<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Deye &#8211; freedomsolar</title>
	<atom:link href="https://freedomsolar.co.th/product-category/deye/feed/" rel="self" type="application/rss+xml" />
	<link>https://freedomsolar.co.th</link>
	<description></description>
	<lastBuildDate>Mon, 16 Feb 2026 05:05:19 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://freedomsolar.co.th/wp-content/uploads/2026/01/cropped-favicon-32x32.webp</url>
	<title>Deye &#8211; freedomsolar</title>
	<link>https://freedomsolar.co.th</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SUN-50K -SG01HP3-EU-BM4</title>
		<link>https://freedomsolar.co.th/product/sun-50k-sg01hp3-eu-bm4/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 05:05:05 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2410</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="250">Model</td>
<td width="150">SUN-29.9K-SG01HP3-EU-BM3</td>
<td width="150">SUN-30K-SG01HP3
-EU-BM3</td>
<td width="150">SUN-35K-SG01HP3
-EU-BM3</td>
<td width="150">SUN-40K-SG01HP3
-EU-BM4</td>
<td width="150">SUN-50K-SG01HP3
-EU-BM4</td>
</tr>
<tr>
<td width="250">Battery Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Battery Type</td>
<td colspan="5" width="750">Lithium-ion</td>
</tr>
<tr>
<td width="250">Battery Voltage Range(V)</td>
<td colspan="5" width="750">160-800</td>
</tr>
<tr>
<td width="250">Max.Charging Current(A)</td>
<td colspan="5" width="750">50+50</td>
</tr>
<tr>
<td width="250">Max.Discharging Current(A)</td>
<td colspan="5" width="750">50+50</td>
</tr>
<tr>
<td width="250">Charging Strategy for Li-ion Battery</td>
<td colspan="5" width="750">Self-adaption to BMS</td>
</tr>
<tr>
<td width="250">Number of battery input</td>
<td colspan="5" width="750">2</td>
</tr>
<tr>
<td width="250">PV String Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>59800</td>
<td>60000</td>
<td>70000</td>
<td>80000</td>
<td>100000</td>
</tr>
<tr>
<td width="250">Max DC Input Power（W）</td>
<td width="150">47840</td>
<td width="150">48000</td>
<td width="150">56000</td>
<td width="150">64000</td>
<td width="150">80000</td>
</tr>
<tr>
<td width="250">Max DC Input Voltage（V）</td>
<td colspan="5" width="750">1000</td>
</tr>
<tr>
<td width="250">Start-up Voltage（V）</td>
<td colspan="5" width="750">180</td>
</tr>
<tr>
<td width="250">MPPT Voltage Range（V）</td>
<td colspan="5" width="750">150-850</td>
</tr>
<tr>
<td width="250">Rated DC Input Voltage(V)</td>
<td colspan="5" width="750">600</td>
</tr>
<tr>
<td width="250">Max Input Short-Circuit Current（A）</td>
<td colspan="3" width="450">55+55+55</td>
<td colspan="2" width="300">55+55+55+55</td>
</tr>
<tr>
<td width="250">Max Operating PV Input Current（A）</td>
<td colspan="3" width="450">36+36+36</td>
<td colspan="2" width="300">36+36+36+36</td>
</tr>
<tr>
<td width="250">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="450">3/2+2+2</td>
<td colspan="2" width="300">4/2+2+2+2</td>
</tr>
<tr>
<td width="250">AC Input/Output Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Active Power（W）</td>
<td width="150">29900</td>
<td width="150">30000</td>
<td width="150">35000</td>
<td width="150">40000</td>
<td width="150">50000</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Apparent Power （VA）</td>
<td width="150">29900</td>
<td width="150">33000</td>
<td width="150">38500</td>
<td width="150">44000</td>
<td width="150">55000</td>
</tr>
<tr>
<td width="250">Peak Power (off-grid)（W）</td>
<td colspan="5" width="750">1.5 times of rated power,10s</td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Current（A）</td>
<td width="150">45.4/43.4</td>
<td width="150">45.5/43.5</td>
<td width="150">53.1/50.8</td>
<td width="150">60.7/58.0</td>
<td width="150">75.8/72.5</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Current（A）</td>
<td width="150">45.4/43.4</td>
<td width="150">50/47.9</td>
<td width="150">58.4/55.8</td>
<td width="150">66.7/63.8</td>
<td width="150">83.4/79.8</td>
</tr>
<tr>
<td width="250">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="5" width="750">200</td>
</tr>
<tr>
<td width="250">Rated Input/Output Voltage/Range(V)</td>
<td colspan="5" width="750">220/380V，230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="250">Grid Connection Form</td>
<td colspan="5" width="750">3L+N+PE</td>
</tr>
<tr>
<td width="250">Rated Input/Output Grid Frequency/Range</td>
<td colspan="5" width="750">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="250">Power Factor Adjustment Range</td>
<td colspan="5" width="750">0.8 leading-0.8 lagging</td>
</tr>
<tr>
<td width="250">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="750">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="250">DC Injection Current</td>
<td colspan="5" width="750">&#60;0.5%ln</td>
</tr>
<tr>
<td width="250">Efficiency</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Max Efficiency</td>
<td colspan="5" width="750">97.60%</td>
</tr>
<tr>
<td width="250">Euro Efficiency</td>
<td colspan="5" width="750">97.0%</td>
</tr>
<tr>
<td width="250">MPPT Efficiency</td>
<td colspan="5" width="750">＞99%</td>
</tr>
<tr>
<td width="250">Equipment Protection</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">
<div>Integrated</div></td>
<td colspan="5" width="750">
<div>
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage</div>
<div>Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit</div>
<div>Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection,</div>
<div>Residual Current Detection</div>
</div></td>
</tr>
<tr>
<td width="250">Surge Protection Level</td>
<td colspan="5" width="750">TYPE II(DC), TYPE II(AC)</td>
</tr>
<tr>
<td width="250">Interface</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Communication Interface</td>
<td colspan="5" width="750">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div></td>
</tr>
<tr>
<td width="250">General Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Operating Temperature Range</td>
<td colspan="5" width="750">-40℃+60℃,＞45℃ Derating</td>
</tr>
<tr>
<td width="250">Permissible Ambient Humidity</td>
<td colspan="5" width="750">0-100%</td>
</tr>
<tr>
<td width="250">Permissible Altitude</td>
<td colspan="5" width="750">2000m</td>
</tr>
<tr>
<td width="250">Noise</td>
<td colspan="5" width="750">≤ 65 dB(A)</td>
</tr>
<tr>
<td width="250">Ingress Protection(IP) Rating</td>
<td colspan="5" width="750">IP 65</td>
</tr>
<tr>
<td width="250">Inverter Topology</td>
<td colspan="5" width="750">Non-Isolated</td>
</tr>
<tr>
<td width="250">Over Voltage Category</td>
<td colspan="5" width="750">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="250">Cabinet size（W*H*D）[mm]</td>
<td colspan="5" width="750">527*894*294（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="250">Weight[kg]</td>
<td colspan="5" width="750">80</td>
</tr>
<tr>
<td width="250">Warranty</td>
<td colspan="5" width="750">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="250">Type Of Cooling</td>
<td colspan="5" width="750">Intelligent air cooling</td>
</tr>
<tr>
<td width="250">Grid Regulation</td>
<td colspan="5" width="750">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="250">Safety EMC/Standard</td>
<td colspan="5" width="750">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 100A</li>
<li>High voltage battery, higher efficiency</li>
<li>6 time periods for battery charging/discharging</li>
<li>Support storing energy from diesel generator</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-40K -SG01HP3-EU-BM4</title>
		<link>https://freedomsolar.co.th/product/sun-40k-sg01hp3-eu-bm4/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 05:04:15 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2408</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="250">Model</td>
<td width="150">SUN-29.9K-SG01HP3-EU-BM3</td>
<td width="150">SUN-30K-SG01HP3
-EU-BM3</td>
<td width="150">SUN-35K-SG01HP3
-EU-BM3</td>
<td width="150">SUN-40K-SG01HP3
-EU-BM4</td>
<td width="150">SUN-50K-SG01HP3
-EU-BM4</td>
</tr>
<tr>
<td width="250">Battery Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Battery Type</td>
<td colspan="5" width="750">Lithium-ion</td>
</tr>
<tr>
<td width="250">Battery Voltage Range(V)</td>
<td colspan="5" width="750">160-800</td>
</tr>
<tr>
<td width="250">Max.Charging Current(A)</td>
<td colspan="5" width="750">50+50</td>
</tr>
<tr>
<td width="250">Max.Discharging Current(A)</td>
<td colspan="5" width="750">50+50</td>
</tr>
<tr>
<td width="250">Charging Strategy for Li-ion Battery</td>
<td colspan="5" width="750">Self-adaption to BMS</td>
</tr>
<tr>
<td width="250">Number of battery input</td>
<td colspan="5" width="750">2</td>
</tr>
<tr>
<td width="250">PV String Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>59800</td>
<td>60000</td>
<td>70000</td>
<td>80000</td>
<td>100000</td>
</tr>
<tr>
<td width="250">Max DC Input Power（W）</td>
<td width="150">47840</td>
<td width="150">48000</td>
<td width="150">56000</td>
<td width="150">64000</td>
<td width="150">80000</td>
</tr>
<tr>
<td width="250">Max DC Input Voltage（V）</td>
<td colspan="5" width="750">1000</td>
</tr>
<tr>
<td width="250">Start-up Voltage（V）</td>
<td colspan="5" width="750">180</td>
</tr>
<tr>
<td width="250">MPPT Voltage Range（V）</td>
<td colspan="5" width="750">150-850</td>
</tr>
<tr>
<td width="250">Rated DC Input Voltage(V)</td>
<td colspan="5" width="750">600</td>
</tr>
<tr>
<td width="250">Max Input Short-Circuit Current（A）</td>
<td colspan="3" width="450">55+55+55</td>
<td colspan="2" width="300">55+55+55+55</td>
</tr>
<tr>
<td width="250">Max Operating PV Input Current（A）</td>
<td colspan="3" width="450">36+36+36</td>
<td colspan="2" width="300">36+36+36+36</td>
</tr>
<tr>
<td width="250">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="450">3/2+2+2</td>
<td colspan="2" width="300">4/2+2+2+2</td>
</tr>
<tr>
<td width="250">AC Input/Output Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Active Power（W）</td>
<td width="150">29900</td>
<td width="150">30000</td>
<td width="150">35000</td>
<td width="150">40000</td>
<td width="150">50000</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Apparent Power （VA）</td>
<td width="150">29900</td>
<td width="150">33000</td>
<td width="150">38500</td>
<td width="150">44000</td>
<td width="150">55000</td>
</tr>
<tr>
<td width="250">Peak Power (off-grid)（W）</td>
<td colspan="5" width="750">1.5 times of rated power,10s</td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Current（A）</td>
<td width="150">45.4/43.4</td>
<td width="150">45.5/43.5</td>
<td width="150">53.1/50.8</td>
<td width="150">60.7/58.0</td>
<td width="150">75.8/72.5</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Current（A）</td>
<td width="150">45.4/43.4</td>
<td width="150">50/47.9</td>
<td width="150">58.4/55.8</td>
<td width="150">66.7/63.8</td>
<td width="150">83.4/79.8</td>
</tr>
<tr>
<td width="250">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="5" width="750">200</td>
</tr>
<tr>
<td width="250">Rated Input/Output Voltage/Range(V)</td>
<td colspan="5" width="750">220/380V，230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="250">Grid Connection Form</td>
<td colspan="5" width="750">3L+N+PE</td>
</tr>
<tr>
<td width="250">Rated Input/Output Grid Frequency/Range</td>
<td colspan="5" width="750">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="250">Power Factor Adjustment Range</td>
<td colspan="5" width="750">0.8 leading-0.8 lagging</td>
</tr>
<tr>
<td width="250">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="750">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="250">DC Injection Current</td>
<td colspan="5" width="750">&#60;0.5%ln</td>
</tr>
<tr>
<td width="250">Efficiency</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Max Efficiency</td>
<td colspan="5" width="750">97.60%</td>
</tr>
<tr>
<td width="250">Euro Efficiency</td>
<td colspan="5" width="750">97.0%</td>
</tr>
<tr>
<td width="250">MPPT Efficiency</td>
<td colspan="5" width="750">＞99%</td>
</tr>
<tr>
<td width="250">Equipment Protection</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">
<div>Integrated</div></td>
<td colspan="5" width="750">
<div>
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage</div>
<div>Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit</div>
<div>Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection,</div>
<div>Residual Current Detection</div>
</div></td>
</tr>
<tr>
<td width="250">Surge Protection Level</td>
<td colspan="5" width="750">TYPE II(DC), TYPE II(AC)</td>
</tr>
<tr>
<td width="250">Interface</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Communication Interface</td>
<td colspan="5" width="750">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div></td>
</tr>
<tr>
<td width="250">General Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Operating Temperature Range</td>
<td colspan="5" width="750">-40℃+60℃,＞45℃ Derating</td>
</tr>
<tr>
<td width="250">Permissible Ambient Humidity</td>
<td colspan="5" width="750">0-100%</td>
</tr>
<tr>
<td width="250">Permissible Altitude</td>
<td colspan="5" width="750">2000m</td>
</tr>
<tr>
<td width="250">Noise</td>
<td colspan="5" width="750">≤ 65 dB(A)</td>
</tr>
<tr>
<td width="250">Ingress Protection(IP) Rating</td>
<td colspan="5" width="750">IP 65</td>
</tr>
<tr>
<td width="250">Inverter Topology</td>
<td colspan="5" width="750">Non-Isolated</td>
</tr>
<tr>
<td width="250">Over Voltage Category</td>
<td colspan="5" width="750">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="250">Cabinet size（W*H*D）[mm]</td>
<td colspan="5" width="750">527*894*294（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="250">Weight[kg]</td>
<td colspan="5" width="750">80</td>
</tr>
<tr>
<td width="250">Warranty</td>
<td colspan="5" width="750">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="250">Type Of Cooling</td>
<td colspan="5" width="750">Intelligent air cooling</td>
</tr>
<tr>
<td width="250">Grid Regulation</td>
<td colspan="5" width="750">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="250">Safety EMC/Standard</td>
<td colspan="5" width="750">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 100A</li>
<li>High voltage battery, higher efficiency</li>
<li>6 time periods for battery charging/discharging</li>
<li>Support storing energy from diesel generator</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-30K -SG01HP3-EU-BM3</title>
		<link>https://freedomsolar.co.th/product/sun-30k-sg01hp3-eu-bm3/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 05:00:02 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2403</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="250">Model</td>
<td width="150">SUN-29.9K-SG01HP3-EU-BM3</td>
<td width="150">SUN-30K-SG01HP3
-EU-BM3</td>
<td width="150">SUN-35K-SG01HP3
-EU-BM3</td>
<td width="150">SUN-40K-SG01HP3
-EU-BM4</td>
<td width="150">SUN-50K-SG01HP3
-EU-BM4</td>
</tr>
<tr>
<td width="250">Battery Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Battery Type</td>
<td colspan="5" width="750">Lithium-ion</td>
</tr>
<tr>
<td width="250">Battery Voltage Range(V)</td>
<td colspan="5" width="750">160-800</td>
</tr>
<tr>
<td width="250">Max.Charging Current(A)</td>
<td colspan="5" width="750">50+50</td>
</tr>
<tr>
<td width="250">Max.Discharging Current(A)</td>
<td colspan="5" width="750">50+50</td>
</tr>
<tr>
<td width="250">Charging Strategy for Li-ion Battery</td>
<td colspan="5" width="750">Self-adaption to BMS</td>
</tr>
<tr>
<td width="250">Number of battery input</td>
<td colspan="5" width="750">2</td>
</tr>
<tr>
<td width="250">PV String Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>59800</td>
<td>60000</td>
<td>70000</td>
<td>80000</td>
<td>100000</td>
</tr>
<tr>
<td width="250">Max DC Input Power（W）</td>
<td width="150">47840</td>
<td width="150">48000</td>
<td width="150">56000</td>
<td width="150">64000</td>
<td width="150">80000</td>
</tr>
<tr>
<td width="250">Max DC Input Voltage（V）</td>
<td colspan="5" width="750">1000</td>
</tr>
<tr>
<td width="250">Start-up Voltage（V）</td>
<td colspan="5" width="750">180</td>
</tr>
<tr>
<td width="250">MPPT Voltage Range（V）</td>
<td colspan="5" width="750">150-850</td>
</tr>
<tr>
<td width="250">Rated DC Input Voltage(V)</td>
<td colspan="5" width="750">600</td>
</tr>
<tr>
<td width="250">Max Input Short-Circuit Current（A）</td>
<td colspan="3" width="450">55+55+55</td>
<td colspan="2" width="300">55+55+55+55</td>
</tr>
<tr>
<td width="250">Max Operating PV Input Current（A）</td>
<td colspan="3" width="450">36+36+36</td>
<td colspan="2" width="300">36+36+36+36</td>
</tr>
<tr>
<td width="250">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="450">3/2+2+2</td>
<td colspan="2" width="300">4/2+2+2+2</td>
</tr>
<tr>
<td width="250">AC Input/Output Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Active Power（W）</td>
<td width="150">29900</td>
<td width="150">30000</td>
<td width="150">35000</td>
<td width="150">40000</td>
<td width="150">50000</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Apparent Power （VA）</td>
<td width="150">29900</td>
<td width="150">33000</td>
<td width="150">38500</td>
<td width="150">44000</td>
<td width="150">55000</td>
</tr>
<tr>
<td width="250">Peak Power (off-grid)（W）</td>
<td colspan="5" width="750">1.5 times of rated power,10s</td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Current（A）</td>
<td width="150">45.4/43.4</td>
<td width="150">45.5/43.5</td>
<td width="150">53.1/50.8</td>
<td width="150">60.7/58.0</td>
<td width="150">75.8/72.5</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Current（A）</td>
<td width="150">45.4/43.4</td>
<td width="150">50/47.9</td>
<td width="150">58.4/55.8</td>
<td width="150">66.7/63.8</td>
<td width="150">83.4/79.8</td>
</tr>
<tr>
<td width="250">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="5" width="750">200</td>
</tr>
<tr>
<td width="250">Rated Input/Output Voltage/Range(V)</td>
<td colspan="5" width="750">220/380V，230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="250">Grid Connection Form</td>
<td colspan="5" width="750">3L+N+PE</td>
</tr>
<tr>
<td width="250">Rated Input/Output Grid Frequency/Range</td>
<td colspan="5" width="750">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="250">Power Factor Adjustment Range</td>
<td colspan="5" width="750">0.8 leading-0.8 lagging</td>
</tr>
<tr>
<td width="250">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="750">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="250">DC Injection Current</td>
<td colspan="5" width="750">&#60;0.5%ln</td>
</tr>
<tr>
<td width="250">Efficiency</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Max Efficiency</td>
<td colspan="5" width="750">97.60%</td>
</tr>
<tr>
<td width="250">Euro Efficiency</td>
<td colspan="5" width="750">97.0%</td>
</tr>
<tr>
<td width="250">MPPT Efficiency</td>
<td colspan="5" width="750">＞99%</td>
</tr>
<tr>
<td width="250">Equipment Protection</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">
<div>Integrated</div></td>
<td colspan="5" width="750">
<div>
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage</div>
<div>Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit</div>
<div>Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection,</div>
<div>Residual Current Detection</div>
</div></td>
</tr>
<tr>
<td width="250">Surge Protection Level</td>
<td colspan="5" width="750">TYPE II(DC), TYPE II(AC)</td>
</tr>
<tr>
<td width="250">Interface</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Communication Interface</td>
<td colspan="5" width="750">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div></td>
</tr>
<tr>
<td width="250">General Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Operating Temperature Range</td>
<td colspan="5" width="750">-40℃+60℃,＞45℃ Derating</td>
</tr>
<tr>
<td width="250">Permissible Ambient Humidity</td>
<td colspan="5" width="750">0-100%</td>
</tr>
<tr>
<td width="250">Permissible Altitude</td>
<td colspan="5" width="750">2000m</td>
</tr>
<tr>
<td width="250">Noise</td>
<td colspan="5" width="750">≤ 65 dB(A)</td>
</tr>
<tr>
<td width="250">Ingress Protection(IP) Rating</td>
<td colspan="5" width="750">IP 65</td>
</tr>
<tr>
<td width="250">Inverter Topology</td>
<td colspan="5" width="750">Non-Isolated</td>
</tr>
<tr>
<td width="250">Over Voltage Category</td>
<td colspan="5" width="750">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="250">Cabinet size（W*H*D）[mm]</td>
<td colspan="5" width="750">527*894*294（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="250">Weight[kg]</td>
<td colspan="5" width="750">80</td>
</tr>
<tr>
<td width="250">Warranty</td>
<td colspan="5" width="750">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="250">Type Of Cooling</td>
<td colspan="5" width="750">Intelligent air cooling</td>
</tr>
<tr>
<td width="250">Grid Regulation</td>
<td colspan="5" width="750">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="250">Safety EMC/Standard</td>
<td colspan="5" width="750">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 100A</li>
<li>High voltage battery, higher efficiency</li>
<li>6 time periods for battery charging/discharging</li>
<li>Support storing energy from diesel generator</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-20K-SG05LP3-EU-SM2</title>
		<link>https://freedomsolar.co.th/product/sun-20k-sg05lp3-eu-sm2/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 04:50:37 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2400</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="262">Modell</td>
<td width="130">SUN-14K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-15K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-16K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-18K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-20K-SG05LP3
-EU-SM2</td>
</tr>
<tr>
<td colspan="6" width="912">Battery Input Data</td>
</tr>
<tr>
<td width="262">Battery Type</td>
<td colspan="5" width="650">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="262">Battery Voltage Range (V)</td>
<td colspan="5" width="650">40-60</td>
</tr>
<tr>
<td width="262">Max. Charging Current (A)</td>
<td width="130">260</td>
<td width="130">280</td>
<td width="130">300</td>
<td width="130">330</td>
<td width="130">350</td>
</tr>
<tr>
<td width="262">Max. Discharging Current (A)</td>
<td width="130">260</td>
<td width="130">280</td>
<td width="130">300</td>
<td width="130">330</td>
<td width="130">350</td>
</tr>
<tr>
<td width="262">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="650">Self-adaption to BMS</td>
</tr>
<tr>
<td width="262">Number of Battery Input</td>
<td colspan="5" width="650">1</td>
</tr>
<tr>
<td colspan="6" width="912">PV String Input Data</td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>28000</td>
<td>30000</td>
<td>32000</td>
<td>36000</td>
<td>40000</td>
</tr>
<tr>
<td width="262">Max. DC Input Power (W)</td>
<td width="130">22400</td>
<td width="130">24000</td>
<td width="130">25600</td>
<td width="130">28800</td>
<td width="130">32000</td>
</tr>
<tr>
<td width="262">Max. DC Input Voltage (V)</td>
<td colspan="5" width="650">800</td>
</tr>
<tr>
<td width="262">Start-up Voltage (V)</td>
<td colspan="5" width="650">160</td>
</tr>
<tr>
<td width="262">MPPT Voltage Range (V)</td>
<td colspan="5" width="650">160-650</td>
</tr>
<tr>
<td width="262">Rated DC Input Voltage (V)</td>
<td colspan="5" width="650">550</td>
</tr>
<tr>
<td width="262">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="650">36+20</td>
</tr>
<tr>
<td width="262">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="650">54+30</td>
</tr>
<tr>
<td width="262">No.of MPPT Trackers/
No.of String PerMPPT Tracker</td>
<td colspan="5" width="650">2/2+1</td>
</tr>
<tr>
<td width="262">AC Input/Output Data</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Rated AC Input/Output Active Power (W)</td>
<td width="130">14000</td>
<td width="130">15000</td>
<td width="130">16000</td>
<td width="130">18000</td>
<td width="130">20000</td>
</tr>
<tr>
<td width="262">Max. AC Input/Output Apparent Power (VA)</td>
<td width="130">15400</td>
<td width="130">16500</td>
<td width="130">17600</td>
<td width="130">19800</td>
<td width="130">22000</td>
</tr>
<tr>
<td width="262">Rated AC Input/Output Current (A)</td>
<td width="130">21.3/20.3</td>
<td width="130">22.8/21.8</td>
<td width="130">24.3/23.2</td>
<td width="130">27.3/26.1</td>
<td width="130">30.4/29</td>
</tr>
<tr>
<td width="262">Max. AC Input/Output Current (A)</td>
<td width="130">23.4/22.4</td>
<td width="130">25/24</td>
<td width="130">26.7/25.6</td>
<td width="130">30/28.7</td>
<td width="130">33.4/31.9</td>
</tr>
<tr>
<td width="262">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="650">70</td>
</tr>
<tr>
<td width="262">Peak Power (off-grid) (W)</td>
<td colspan="5" width="650">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="262">Power Factor Adjustment Range</td>
<td colspan="5" width="650">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="262">Rated Input/Output Voltage/Range (V)</td>
<td colspan="5" width="650">220/380V, 230/400V  0.85Un-1.1Un</td>
</tr>
<tr>
<td width="262">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="650">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="262">Grid Connection Form</td>
<td colspan="5" width="650">3L+N+PE</td>
</tr>
<tr>
<td width="262">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="650">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="262">DC Component of Grid</td>
<td colspan="5" width="650">&#60;0.5% In</td>
</tr>
<tr>
<td width="262">Eﬃciency</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Max. Efﬁciency</td>
<td colspan="5" width="650">97.6%</td>
</tr>
<tr>
<td width="262">Euro Efﬁciency</td>
<td colspan="5" width="650">97.0%</td>
</tr>
<tr>
<td width="262">MPPTEfﬁciency</td>
<td colspan="5" width="650">&#62;99%</td>
</tr>
<tr>
<td width="262">Equipment Protection</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Integrated</td>
<td colspan="5" width="650">
<div>DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,</div>
<div>AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,</div>
<div>Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),</div>
<div>Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,</div>
<div>DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level</div></td>
</tr>
<tr>
<td width="262">Surge Protection Level</td>
<td colspan="5" width="650">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="262">Interface</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Communication Interface</td>
<td colspan="5" width="650">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div></td>
</tr>
<tr>
<td width="262">General Data</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Operating Temperature Range (℃)</td>
<td colspan="5" width="650">-40 to +60℃, &#62;45℃ Derating</td>
</tr>
<tr>
<td width="262">Permissible Ambient Humidity</td>
<td colspan="5" width="650">0-100%</td>
</tr>
<tr>
<td width="262">Permissible Altitude</td>
<td colspan="5" width="650">3000m</td>
</tr>
<tr>
<td width="262">Noise</td>
<td colspan="5" width="650">≤60</td>
</tr>
<tr>
<td width="262">Ingress Protection(IP) Rating</td>
<td colspan="5" width="650">IP 65</td>
</tr>
<tr>
<td width="262">Inverter Topology</td>
<td colspan="5" width="650">Non-Isolated</td>
</tr>
<tr>
<td width="262">Over Voltage Category</td>
<td colspan="5" width="650">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="262">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="650">456×750×268.5 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="262">Weight (kg)</td>
<td colspan="5" width="650">50.6</td>
</tr>
<tr>
<td width="262">Type of Cooling</td>
<td colspan="5" width="650">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="262">Warranty</td>
<td colspan="5" width="650">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="262">Grid Regulation</td>
<td colspan="5" width="650">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="262">Safety / EMC Standard</td>
<td colspan="5" width="650">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 350A</li>
<li>Support storing energy from diesel generator</li>
<li>48V low voltage battery, transformer isolation design</li>
<li>6 time periods for battery charging/discharging</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-15K-SG05LP3-EU-SM2</title>
		<link>https://freedomsolar.co.th/product/sun-15k-sg05lp3-eu-sm2/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 04:40:06 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2394</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="262">Modell</td>
<td width="130">SUN-14K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-15K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-16K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-18K-SG05LP3
-EU-SM2</td>
<td width="130">SUN-20K-SG05LP3
-EU-SM2</td>
</tr>
<tr>
<td colspan="6" width="912">Battery Input Data</td>
</tr>
<tr>
<td width="262">Battery Type</td>
<td colspan="5" width="650">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="262">Battery Voltage Range (V)</td>
<td colspan="5" width="650">40-60</td>
</tr>
<tr>
<td width="262">Max. Charging Current (A)</td>
<td width="130">260</td>
<td width="130">280</td>
<td width="130">300</td>
<td width="130">330</td>
<td width="130">350</td>
</tr>
<tr>
<td width="262">Max. Discharging Current (A)</td>
<td width="130">260</td>
<td width="130">280</td>
<td width="130">300</td>
<td width="130">330</td>
<td width="130">350</td>
</tr>
<tr>
<td width="262">Charging Strategy forLi-ion Battery</td>
<td colspan="5" width="650">Self-adaption to BMS</td>
</tr>
<tr>
<td width="262">Number of Battery Input</td>
<td colspan="5" width="650">1</td>
</tr>
<tr>
<td colspan="6" width="912">PV String Input Data</td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>28000</td>
<td>30000</td>
<td>32000</td>
<td>36000</td>
<td>40000</td>
</tr>
<tr>
<td width="262">Max. DC Input Power (W)</td>
<td width="130">22400</td>
<td width="130">24000</td>
<td width="130">25600</td>
<td width="130">28800</td>
<td width="130">32000</td>
</tr>
<tr>
<td width="262">Max. DC Input Voltage (V)</td>
<td colspan="5" width="650">800</td>
</tr>
<tr>
<td width="262">Start-up Voltage (V)</td>
<td colspan="5" width="650">160</td>
</tr>
<tr>
<td width="262">MPPT Voltage Range (V)</td>
<td colspan="5" width="650">160-650</td>
</tr>
<tr>
<td width="262">Rated DC Input Voltage (V)</td>
<td colspan="5" width="650">550</td>
</tr>
<tr>
<td width="262">Max. Operating PV Input Current (A)</td>
<td colspan="5" width="650">36+20</td>
</tr>
<tr>
<td width="262">Max. Input Short-Circuit Current (A)</td>
<td colspan="5" width="650">54+30</td>
</tr>
<tr>
<td width="262">No.of MPPT Trackers/
No.of String PerMPPT Tracker</td>
<td colspan="5" width="650">2/2+1</td>
</tr>
<tr>
<td width="262">AC Input/Output Data</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Rated AC Input/Output Active Power (W)</td>
<td width="130">14000</td>
<td width="130">15000</td>
<td width="130">16000</td>
<td width="130">18000</td>
<td width="130">20000</td>
</tr>
<tr>
<td width="262">Max. AC Input/Output Apparent Power (VA)</td>
<td width="130">15400</td>
<td width="130">16500</td>
<td width="130">17600</td>
<td width="130">19800</td>
<td width="130">22000</td>
</tr>
<tr>
<td width="262">Rated AC Input/Output Current (A)</td>
<td width="130">21.3/20.3</td>
<td width="130">22.8/21.8</td>
<td width="130">24.3/23.2</td>
<td width="130">27.3/26.1</td>
<td width="130">30.4/29</td>
</tr>
<tr>
<td width="262">Max. AC Input/Output Current (A)</td>
<td width="130">23.4/22.4</td>
<td width="130">25/24</td>
<td width="130">26.7/25.6</td>
<td width="130">30/28.7</td>
<td width="130">33.4/31.9</td>
</tr>
<tr>
<td width="262">Max. Continuous AC Passthrough (grid to load) (A)</td>
<td colspan="5" width="650">70</td>
</tr>
<tr>
<td width="262">Peak Power (off-grid) (W)</td>
<td colspan="5" width="650">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="262">Power Factor Adjustment Range</td>
<td colspan="5" width="650">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="262">Rated Input/Output Voltage/Range (V)</td>
<td colspan="5" width="650">220/380V, 230/400V  0.85Un-1.1Un</td>
</tr>
<tr>
<td width="262">Rated Input/Output Grid Frequency/Range(Hz)</td>
<td colspan="5" width="650">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="262">Grid Connection Form</td>
<td colspan="5" width="650">3L+N+PE</td>
</tr>
<tr>
<td width="262">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="650">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="262">DC Component of Grid</td>
<td colspan="5" width="650">&#60;0.5% In</td>
</tr>
<tr>
<td width="262">Eﬃciency</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Max. Efﬁciency</td>
<td colspan="5" width="650">97.6%</td>
</tr>
<tr>
<td width="262">Euro Efﬁciency</td>
<td colspan="5" width="650">97.0%</td>
</tr>
<tr>
<td width="262">MPPTEfﬁciency</td>
<td colspan="5" width="650">&#62;99%</td>
</tr>
<tr>
<td width="262">Equipment Protection</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Integrated</td>
<td colspan="5" width="650">
<div>DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,</div>
<div>AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,</div>
<div>Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),</div>
<div>Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,</div>
<div>DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level</div></td>
</tr>
<tr>
<td width="262">Surge Protection Level</td>
<td colspan="5" width="650">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="262">Interface</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Communication Interface</td>
<td colspan="5" width="650">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div></td>
</tr>
<tr>
<td width="262">General Data</td>
<td colspan="5" width="650"></td>
</tr>
<tr>
<td width="262">Operating Temperature Range (℃)</td>
<td colspan="5" width="650">-40 to +60℃, &#62;45℃ Derating</td>
</tr>
<tr>
<td width="262">Permissible Ambient Humidity</td>
<td colspan="5" width="650">0-100%</td>
</tr>
<tr>
<td width="262">Permissible Altitude</td>
<td colspan="5" width="650">3000m</td>
</tr>
<tr>
<td width="262">Noise</td>
<td colspan="5" width="650">≤60</td>
</tr>
<tr>
<td width="262">Ingress Protection(IP) Rating</td>
<td colspan="5" width="650">IP 65</td>
</tr>
<tr>
<td width="262">Inverter Topology</td>
<td colspan="5" width="650">Non-Isolated</td>
</tr>
<tr>
<td width="262">Over Voltage Category</td>
<td colspan="5" width="650">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="262">Cabinet Size (WxHxD mm)</td>
<td colspan="5" width="650">456×750×268.5 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="262">Weight (kg)</td>
<td colspan="5" width="650">50.6</td>
</tr>
<tr>
<td width="262">Type of Cooling</td>
<td colspan="5" width="650">Intelligent Air Cooling</td>
</tr>
<tr>
<td width="262">Warranty</td>
<td colspan="5" width="650">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="262">Grid Regulation</td>
<td colspan="5" width="650">IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="262">Safety / EMC Standard</td>
<td colspan="5" width="650">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 350A</li>
<li>Support storing energy from diesel generator</li>
<li>48V low voltage battery, transformer isolation design</li>
<li>6 time periods for battery charging/discharging</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-10-SG04LP3-EU</title>
		<link>https://freedomsolar.co.th/product/sun-10-sg04lp3-eu/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 04:22:16 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2392</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="250">Model</td>
<td width="150">SUN-5K-SG04LP3-EU</td>
<td width="150">SUN-6K-SG04LP3-EU</td>
<td width="150">SUN-8K-SG04LP3-EU</td>
<td width="150">SUN-10K-SG04LP3-EU</td>
<td width="150">SUN-12K-SG04LP3-EU</td>
</tr>
<tr>
<td width="250">Battery Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Battery Type</td>
<td colspan="5" width="750">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="250">Battery Voltage Range(V)</td>
<td colspan="5" width="750">40-60</td>
</tr>
<tr>
<td width="250">Max.Charging Current(A)</td>
<td width="750">120</td>
<td>150</td>
<td>190</td>
<td>210</td>
<td>240</td>
</tr>
<tr>
<td width="250">Max.Discharging Current(A)</td>
<td width="750">120</td>
<td>150</td>
<td>190</td>
<td>210</td>
<td>240</td>
</tr>
<tr>
<td width="250">Charging Strategy for Li-ion Battery</td>
<td colspan="5" width="750">Self-adaption to BMS</td>
</tr>
<tr>
<td width="250">Number of battery input</td>
<td colspan="5" width="750">1</td>
</tr>
<tr>
<td width="250">PV String Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
</tr>
<tr>
<td width="250">Max PV Input Power（W）</td>
<td width="150">7500</td>
<td width="150">9000</td>
<td width="150">12000</td>
<td width="150">15000</td>
<td width="150">18000</td>
</tr>
<tr>
<td width="250">MaxPV Input Voltage（V）</td>
<td colspan="5" width="750">800</td>
</tr>
<tr>
<td width="250">Start-up Voltage（V）</td>
<td colspan="5" width="750">160</td>
</tr>
<tr>
<td width="250">MPPT Voltage Range（V）</td>
<td colspan="5" width="750">200-650</td>
</tr>
<tr>
<td width="250">Rated PV Input Voltage(V)</td>
<td colspan="5" width="750">550</td>
</tr>
<tr>
<td width="250">Max. Operating PV Input Current (A)</td>
<td colspan="3" width="450">13+13</td>
<td colspan="2" width="300">26+13</td>
</tr>
<tr>
<td width="250">Max. Input Short-Circuit Current (A)</td>
<td colspan="3" width="450">17+17</td>
<td colspan="2" width="300">34+17</td>
</tr>
<tr>
<td width="250">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="450">2/1+1</td>
<td colspan="2" width="300">2/2+1</td>
</tr>
<tr>
<td width="250">AC Input/Output Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Active Power（W）</td>
<td width="150">5000</td>
<td width="150">6000</td>
<td width="150">8000</td>
<td width="150">10000</td>
<td width="150">12000</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Apparent Power （VA）</td>
<td width="150">5500</td>
<td width="150">6600</td>
<td width="150">8800</td>
<td width="150">11000</td>
<td width="150">13200</td>
</tr>
<tr>
<td width="250">Peak Power (off-grid)（W）</td>
<td colspan="5" width="750">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Current（A）</td>
<td width="150">7.6/7.2</td>
<td width="150">9.1/8.7</td>
<td width="150">12.1/11.6</td>
<td width="150">15.2/14.5</td>
<td width="150">18.2/17.4</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Current（A）</td>
<td width="150">8.4/8</td>
<td width="150">10/9.6</td>
<td width="150">13.4/12.8</td>
<td width="150">16.7/15.9</td>
<td width="150">20/19.1</td>
</tr>
<tr>
<td width="250">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="5" width="750">45</td>
</tr>
<tr>
<td width="250">Rated Input/Output Voltage/Range(V)</td>
<td colspan="5" width="750">220/380V，230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="250">Grid Connection Form</td>
<td colspan="5" width="750">3L+N+PE</td>
</tr>
<tr>
<td width="250">Rated Input/Output Grid Frequency/Range</td>
<td colspan="5" width="750">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="250">Power Factor Adjustment Range</td>
<td colspan="5" width="750">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="250">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="750">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="250">DC Injection Current</td>
<td colspan="5" width="750">&#60;0.5%ln</td>
</tr>
<tr>
<td width="250">Efficiency</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Max Efficiency</td>
<td colspan="5" width="750">97.6%</td>
</tr>
<tr>
<td width="250">Euro Efficiency</td>
<td colspan="5" width="750">97.0%</td>
</tr>
<tr>
<td width="250">MPPT Efficiency</td>
<td colspan="5" width="750">＞99%</td>
</tr>
<tr>
<td width="250">Equipment Protection</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Integrated</td>
<td colspan="5" width="750">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage</div>
<div>Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter</div>
<div>(optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection,</div>
<div>Residual Current Detection</div></td>
</tr>
<tr>
<td width="250">Surge Protection Level</td>
<td colspan="5" width="750">TYPE II(DC), TYPE II(AC)</td>
</tr>
<tr>
<td width="250">Interface</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Communication Interface</td>
<td colspan="5" width="750">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">GPRS/WIFI/Bluetooth/4G/LAN(optional)</td>
</tr>
<tr>
<td width="250">General Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Operating Temperature Range</td>
<td colspan="5" width="750">-40 to +60℃, &#62;45℃ Derating</td>
</tr>
<tr>
<td width="250">Permissible Ambient Humidity</td>
<td colspan="5" width="750">0-100%</td>
</tr>
<tr>
<td width="250">Permissible Altitude</td>
<td colspan="5" width="750">2000m</td>
</tr>
<tr>
<td width="250">Noise</td>
<td colspan="5" width="750">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="250">Ingress Protection(IP) Rating</td>
<td colspan="5" width="750">IP 65</td>
</tr>
<tr>
<td width="250">Inverter Topology</td>
<td colspan="5" width="750">Non-Isolated</td>
</tr>
<tr>
<td width="250">Over Voltage Category</td>
<td colspan="5" width="750">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="250">Cabinet size（W*H*D）[mm]</td>
<td colspan="5" width="750">422×658×254（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="250">Weight[kg]</td>
<td colspan="5" width="750">38</td>
</tr>
<tr>
<td width="250">Warranty</td>
<td colspan="5" width="750">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="250">Type Of Cooling</td>
<td colspan="5" width="750">Intelligent air cooling</td>
</tr>
<tr>
<td width="250">Grid Regulation</td>
<td colspan="5" width="750">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G98,G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="250">Safety EMC/Standard</td>
<td colspan="5" width="750">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
&#160;]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 240A</li>
<li>Support storing energy from diesel generator</li>
<li>48V low voltage battery, transformer isolation design</li>
<li>6 time periods for battery charging/discharging</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-10-SG05LP1-EU</title>
		<link>https://freedomsolar.co.th/product/sun-10-sg05lp1-eu/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 03:58:45 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2390</guid>

					<description><![CDATA[<table border="1">
<tbody>
<tr>
<td width="176"><strong>Model</strong></td>
<td width="125"><strong>SUN-3.6K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-5K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-6K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-7K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-7.6K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-8K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-10K-SG05LP1-EU</strong></td>
</tr>
<tr>
<td width="176"><strong>Battery Input Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Battery Type</td>
<td colspan="7" width="875">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="176">Battery Voltage Range(V)</td>
<td colspan="7" width="875">40-60</td>
</tr>
<tr>
<td width="176">Max.Charging Current(A)</td>
<td width="125">90</td>
<td width="125">120</td>
<td width="125">135</td>
<td width="125">175</td>
<td width="125">190</td>
<td width="125">190</td>
<td width="125">210</td>
</tr>
<tr>
<td width="176">Max.Discharging Current(A)</td>
<td width="125">90</td>
<td width="125">120</td>
<td width="125">135</td>
<td width="125">175</td>
<td width="125">190</td>
<td width="125">190</td>
<td width="125">210</td>
</tr>
<tr>
<td width="176">Charging Strategy for Li-ion Battery</td>
<td colspan="7" width="875">Self-adaption to BMS</td>
</tr>
<tr>
<td width="176">Number of battery input</td>
<td colspan="7" width="875">1</td>
</tr>
<tr>
<td width="176"><strong>PV String Input Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Max. PV Access Power (W)</td>
<td width="125">7200</td>
<td width="125">10000</td>
<td width="125">12000</td>
<td width="125">14000</td>
<td width="125">15200</td>
<td width="125">16000</td>
<td width="125">20000</td>
</tr>
<tr>
<td width="176">Max PV Input Power（W）</td>
<td width="125">5760</td>
<td width="125">8000</td>
<td width="125">9600</td>
<td width="125">11200</td>
<td width="125">12160</td>
<td width="125">12800</td>
<td width="125">16000</td>
</tr>
<tr>
<td width="176">Max PV Input Voltage（V）</td>
<td colspan="7" width="875">500</td>
</tr>
<tr>
<td width="176">Start-up Voltage（V）</td>
<td colspan="7" width="875">125</td>
</tr>
<tr>
<td width="176">MPPT Voltage Range（V）</td>
<td colspan="7" width="875">150-425</td>
</tr>
<tr>
<td width="176">Rated PV Input Voltage(V)</td>
<td colspan="7" width="875">370</td>
</tr>
<tr>
<td width="176">Max Operating PV Input Current（A）</td>
<td colspan="3" width="375">13+13</td>
<td colspan="4" width="500">26+26</td>
</tr>
<tr>
<td width="176">Max Input Short-Circuit Current（A）</td>
<td colspan="3" width="375">17+17</td>
<td colspan="4" width="500">34+34</td>
</tr>
<tr>
<td width="176">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="375">2/1+1</td>
<td colspan="4" width="500">2/2+2</td>
</tr>
<tr>
<td width="176"><strong>AC Input/Output Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Rated AC Input/Output Active Power（W）</td>
<td width="125">3600</td>
<td width="125">5000</td>
<td width="125">6000</td>
<td width="125">7000</td>
<td width="125">7600</td>
<td width="125">8000</td>
<td width="125">10000</td>
</tr>
<tr>
<td width="176">Max AC Input/Output Apparent Power （VA）</td>
<td width="125">3960</td>
<td width="125">5500</td>
<td width="125">6600</td>
<td width="125">7700</td>
<td width="125">8360</td>
<td width="125">8800</td>
<td width="125">11000</td>
</tr>
<tr>
<td width="176">Rated AC Input/Output Current（A）</td>
<td width="125">16.4/15.7</td>
<td width="125">22.7/21.7</td>
<td width="125">27.3/26.1</td>
<td width="125">31.9/30.5</td>
<td width="125">34.5/33</td>
<td width="125">36.4/34.8</td>
<td width="125">45.5/43.5</td>
</tr>
<tr>
<td width="176">Max AC Input/Output Current（A）</td>
<td width="125">18/17.2</td>
<td width="125">25/23.9</td>
<td width="125">30/28.7</td>
<td width="125">35.0/33.5</td>
<td width="125">38/36.3</td>
<td width="125">40/38.3</td>
<td width="125">50/47.9</td>
</tr>
<tr>
<td width="176">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="2" width="250">35</td>
<td width="125">40</td>
<td colspan="4" width="500">50</td>
</tr>
<tr>
<td width="176">Peak Power (off-grid)（W）</td>
<td colspan="7" width="875">2 times of rated power,10s</td>
</tr>
<tr>
<td width="176">Rated Input/Output Voltage/Range(V)</td>
<td colspan="7" width="875">220V/230 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="176">Grid Connection Form</td>
<td colspan="7" width="875">L+N+PE</td>
</tr>
<tr>
<td width="176">Rated Input/Output Grid Frequency/Range</td>
<td colspan="7" width="875">50Hz/45Hz-55Hz     60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="176">Power Factor Adjustment Range</td>
<td colspan="7" width="875">0.8 leading-0.8lagging</td>
</tr>
<tr>
<td width="176">Total Current Harmonic Distortion THDi</td>
<td colspan="7" width="875">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="176">DC Injection Current</td>
<td colspan="7" width="875">&#60;0.5%ln</td>
</tr>
<tr>
<td width="176"><strong>Efficiency</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Max Efficiency</td>
<td colspan="7" width="875">97.60%</td>
</tr>
<tr>
<td width="176">Euro Efficiency</td>
<td colspan="7" width="875">96.50%</td>
</tr>
<tr>
<td width="176">MPPT Efficiency</td>
<td colspan="7" width="875">＞99%</td>
</tr>
<tr>
<td width="176"><strong>Equipment Protection</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Integrated</td>
<td colspan="7" width="875">DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</td>
</tr>
<tr>
<td width="176">Surge Protection Level</td>
<td colspan="7" width="875">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="176"><strong>Interface</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Communication Interface</td>
<td colspan="7" width="875">WIFI/RS485/CAN</td>
</tr>
<tr>
<td width="176">LCD/LED Display</td>
<td colspan="7" width="875">LCD</td>
</tr>
<tr>
<td width="176"><strong>General Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Operating Temperature Range</td>
<td colspan="7" width="875">-40 to +60℃, &#62;45℃ Derating</td>
</tr>
<tr>
<td width="176">Permissible Ambient Humidity</td>
<td colspan="7" width="875">0~100%</td>
</tr>
<tr>
<td width="176">Permissible Altitude</td>
<td colspan="7" width="875">2500m</td>
</tr>
<tr>
<td width="176">Noise</td>
<td colspan="7" width="875">＜45</td>
</tr>
<tr>
<td width="176">Ingress Protection(IP) Rating</td>
<td colspan="7" width="875">IP 65</td>
</tr>
<tr>
<td width="176">Inverter Topology</td>
<td colspan="7" width="875">Non-Isolated</td>
</tr>
<tr>
<td width="176">Over Voltage Category</td>
<td colspan="7" width="875">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="176">Cabinet size（W*H*D）[mm]</td>
<td colspan="7" width="875">330×580×232 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="176">Weight[kg]</td>
<td colspan="7" width="875">24.9</td>
</tr>
<tr>
<td width="176">Warranty</td>
<td colspan="7" width="875">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="176">Type Of Cooling</td>
<td colspan="7" width="875">Intelligent air cooling</td>
</tr>
<tr>
<td width="176">Grid Regulation</td>
<td colspan="7" width="875">IEC 61727,IEC 62116,CEI 0-21,EN 50549，NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="176">Safety EMC/Standard</td>
<td colspan="7" width="875">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>Colorful touch LCD, IP65 protection degree</li>
<li>AC couple to retrofit existing solar system</li>
<li>Max. 16 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 190A</li>
<li>6 time periods for battery charging/discharging</li>
<li>Support storing energy from diesel generator</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-5-SG04LP3-EU</title>
		<link>https://freedomsolar.co.th/product/sun-5-sg04lp3-eu/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 03:42:10 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2380</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td width="250">Model</td>
<td width="150">SUN-5K-SG04LP3-EU</td>
<td width="150">SUN-6K-SG04LP3-EU</td>
<td width="150">SUN-8K-SG04LP3-EU</td>
<td width="150">SUN-10K-SG04LP3-EU</td>
<td width="150">SUN-12K-SG04LP3-EU</td>
</tr>
<tr>
<td width="250">Battery Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Battery Type</td>
<td colspan="5" width="750">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="250">Battery Voltage Range(V)</td>
<td colspan="5" width="750">40-60</td>
</tr>
<tr>
<td width="250">Max.Charging Current(A)</td>
<td width="750">120</td>
<td>150</td>
<td>190</td>
<td>210</td>
<td>240</td>
</tr>
<tr>
<td width="250">Max.Discharging Current(A)</td>
<td width="750">120</td>
<td>150</td>
<td>190</td>
<td>210</td>
<td>240</td>
</tr>
<tr>
<td width="250">Charging Strategy for Li-ion Battery</td>
<td colspan="5" width="750">Self-adaption to BMS</td>
</tr>
<tr>
<td width="250">Number of battery input</td>
<td colspan="5" width="750">1</td>
</tr>
<tr>
<td width="250">PV String Input Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td>
<div>Max. PV Access Power (W)</div></td>
<td>10000</td>
<td>12000</td>
<td>16000</td>
<td>20000</td>
<td>24000</td>
</tr>
<tr>
<td width="250">Max PV Input Power（W）</td>
<td width="150">7500</td>
<td width="150">9000</td>
<td width="150">12000</td>
<td width="150">15000</td>
<td width="150">18000</td>
</tr>
<tr>
<td width="250">MaxPV Input Voltage（V）</td>
<td colspan="5" width="750">800</td>
</tr>
<tr>
<td width="250">Start-up Voltage（V）</td>
<td colspan="5" width="750">160</td>
</tr>
<tr>
<td width="250">MPPT Voltage Range（V）</td>
<td colspan="5" width="750">200-650</td>
</tr>
<tr>
<td width="250">Rated PV Input Voltage(V)</td>
<td colspan="5" width="750">550</td>
</tr>
<tr>
<td width="250">Max. Operating PV Input Current (A)</td>
<td colspan="3" width="450">13+13</td>
<td colspan="2" width="300">26+13</td>
</tr>
<tr>
<td width="250">Max. Input Short-Circuit Current (A)</td>
<td colspan="3" width="450">17+17</td>
<td colspan="2" width="300">34+17</td>
</tr>
<tr>
<td width="250">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="450">2/1+1</td>
<td colspan="2" width="300">2/2+1</td>
</tr>
<tr>
<td width="250">AC Input/Output Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Active Power（W）</td>
<td width="150">5000</td>
<td width="150">6000</td>
<td width="150">8000</td>
<td width="150">10000</td>
<td width="150">12000</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Apparent Power （VA）</td>
<td width="150">5500</td>
<td width="150">6600</td>
<td width="150">8800</td>
<td width="150">11000</td>
<td width="150">13200</td>
</tr>
<tr>
<td width="250">Peak Power (off-grid)（W）</td>
<td colspan="5" width="750">2 times of rated power, 10s</td>
</tr>
<tr>
<td width="250">Rated AC Input/Output Current（A）</td>
<td width="150">7.6/7.2</td>
<td width="150">9.1/8.7</td>
<td width="150">12.1/11.6</td>
<td width="150">15.2/14.5</td>
<td width="150">18.2/17.4</td>
</tr>
<tr>
<td width="250">Max AC Input/Output Current（A）</td>
<td width="150">8.4/8</td>
<td width="150">10/9.6</td>
<td width="150">13.4/12.8</td>
<td width="150">16.7/15.9</td>
<td width="150">20/19.1</td>
</tr>
<tr>
<td width="250">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="5" width="750">45</td>
</tr>
<tr>
<td width="250">Rated Input/Output Voltage/Range(V)</td>
<td colspan="5" width="750">220/380V，230/400V 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="250">Grid Connection Form</td>
<td colspan="5" width="750">3L+N+PE</td>
</tr>
<tr>
<td width="250">Rated Input/Output Grid Frequency/Range</td>
<td colspan="5" width="750">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="250">Power Factor Adjustment Range</td>
<td colspan="5" width="750">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="250">Total Current Harmonic Distortion THDi</td>
<td colspan="5" width="750">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="250">DC Injection Current</td>
<td colspan="5" width="750">&#60;0.5%ln</td>
</tr>
<tr>
<td width="250">Efficiency</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Max Efficiency</td>
<td colspan="5" width="750">97.6%</td>
</tr>
<tr>
<td width="250">Euro Efficiency</td>
<td colspan="5" width="750">97.0%</td>
</tr>
<tr>
<td width="250">MPPT Efficiency</td>
<td colspan="5" width="750">＞99%</td>
</tr>
<tr>
<td width="250">Equipment Protection</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Integrated</td>
<td colspan="5" width="750">
<div>DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage</div>
<div>Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter</div>
<div>(optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection,</div>
<div>Residual Current Detection</div></td>
</tr>
<tr>
<td width="250">Surge Protection Level</td>
<td colspan="5" width="750">TYPE II(DC), TYPE II(AC)</td>
</tr>
<tr>
<td width="250">Interface</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Communication Interface</td>
<td colspan="5" width="750">RS485/RS232/CAN</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div></td>
<td colspan="5">GPRS/WIFI/Bluetooth/4G/LAN(optional)</td>
</tr>
<tr>
<td width="250">General Data</td>
<td colspan="5" width="750"></td>
</tr>
<tr>
<td width="250">Operating Temperature Range</td>
<td colspan="5" width="750">-40 to +60℃, &#62;45℃ Derating</td>
</tr>
<tr>
<td width="250">Permissible Ambient Humidity</td>
<td colspan="5" width="750">0-100%</td>
</tr>
<tr>
<td width="250">Permissible Altitude</td>
<td colspan="5" width="750">2000m</td>
</tr>
<tr>
<td width="250">Noise</td>
<td colspan="5" width="750">≤ 55 dB(A)</td>
</tr>
<tr>
<td width="250">Ingress Protection(IP) Rating</td>
<td colspan="5" width="750">IP 65</td>
</tr>
<tr>
<td width="250">Inverter Topology</td>
<td colspan="5" width="750">Non-Isolated</td>
</tr>
<tr>
<td width="250">Over Voltage Category</td>
<td colspan="5" width="750">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="250">Cabinet size（W*H*D）[mm]</td>
<td colspan="5" width="750">422×658×254（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="250">Weight[kg]</td>
<td colspan="5" width="750">38</td>
</tr>
<tr>
<td width="250">Warranty</td>
<td colspan="5" width="750">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="250">Type Of Cooling</td>
<td colspan="5" width="750">Intelligent air cooling</td>
</tr>
<tr>
<td width="250">Grid Regulation</td>
<td colspan="5" width="750">IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G98,G99, VDE-AR-N 4105</td>
</tr>
<tr>
<td width="250">Safety EMC/Standard</td>
<td colspan="5" width="750">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
&#160;]]></description>
										<content:encoded><![CDATA[<ul>
<li>100% unbalanced output</li>
<li>AC couple to retrofifit existing solar system</li>
<li>Max. 10 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 240A</li>
<li>Support storing energy from diesel generator</li>
<li>48V low voltage battery, transformer isolation design</li>
<li>6 time periods for battery charging/discharging</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SUN-5-SG05LP1-EU</title>
		<link>https://freedomsolar.co.th/product/sun-5-sg05lp1-eu/</link>
		
		<dc:creator><![CDATA[Champ]]></dc:creator>
		<pubDate>Mon, 16 Feb 2026 03:18:26 +0000</pubDate>
				<guid isPermaLink="false">https://freedomsolar.co.th/?post_type=product&#038;p=2375</guid>

					<description><![CDATA[<table border="1">
<tbody>
<tr>
<td width="176"><strong>Model</strong></td>
<td width="125"><strong>SUN-3.6K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-5K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-6K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-7K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-7.6K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-8K-SG05LP1-EU</strong></td>
<td width="125"><strong>SUN-10K-SG05LP1-EU</strong></td>
</tr>
<tr>
<td width="176"><strong>Battery Input Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Battery Type</td>
<td colspan="7" width="875">Lead-acid or Lithium-ion</td>
</tr>
<tr>
<td width="176">Battery Voltage Range(V)</td>
<td colspan="7" width="875">40-60</td>
</tr>
<tr>
<td width="176">Max.Charging Current(A)</td>
<td width="125">90</td>
<td width="125">120</td>
<td width="125">135</td>
<td width="125">175</td>
<td width="125">190</td>
<td width="125">190</td>
<td width="125">210</td>
</tr>
<tr>
<td width="176">Max.Discharging Current(A)</td>
<td width="125">90</td>
<td width="125">120</td>
<td width="125">135</td>
<td width="125">175</td>
<td width="125">190</td>
<td width="125">190</td>
<td width="125">210</td>
</tr>
<tr>
<td width="176">Charging Strategy for Li-ion Battery</td>
<td colspan="7" width="875">Self-adaption to BMS</td>
</tr>
<tr>
<td width="176">Number of battery input</td>
<td colspan="7" width="875">1</td>
</tr>
<tr>
<td width="176"><strong>PV String Input Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Max. PV Access Power (W)</td>
<td width="125">7200</td>
<td width="125">10000</td>
<td width="125">12000</td>
<td width="125">14000</td>
<td width="125">15200</td>
<td width="125">16000</td>
<td width="125">20000</td>
</tr>
<tr>
<td width="176">Max PV Input Power（W）</td>
<td width="125">5760</td>
<td width="125">8000</td>
<td width="125">9600</td>
<td width="125">11200</td>
<td width="125">12160</td>
<td width="125">12800</td>
<td width="125">16000</td>
</tr>
<tr>
<td width="176">Max PV Input Voltage（V）</td>
<td colspan="7" width="875">500</td>
</tr>
<tr>
<td width="176">Start-up Voltage（V）</td>
<td colspan="7" width="875">125</td>
</tr>
<tr>
<td width="176">MPPT Voltage Range（V）</td>
<td colspan="7" width="875">150-425</td>
</tr>
<tr>
<td width="176">Rated PV Input Voltage(V)</td>
<td colspan="7" width="875">370</td>
</tr>
<tr>
<td width="176">Max Operating PV Input Current（A）</td>
<td colspan="3" width="375">13+13</td>
<td colspan="4" width="500">26+26</td>
</tr>
<tr>
<td width="176">Max Input Short-Circuit Current（A）</td>
<td colspan="3" width="375">17+17</td>
<td colspan="4" width="500">34+34</td>
</tr>
<tr>
<td width="176">No.of MPP Trackers/No.of String Per MPP Tracker</td>
<td colspan="3" width="375">2/1+1</td>
<td colspan="4" width="500">2/2+2</td>
</tr>
<tr>
<td width="176"><strong>AC Input/Output Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Rated AC Input/Output Active Power（W）</td>
<td width="125">3600</td>
<td width="125">5000</td>
<td width="125">6000</td>
<td width="125">7000</td>
<td width="125">7600</td>
<td width="125">8000</td>
<td width="125">10000</td>
</tr>
<tr>
<td width="176">Max AC Input/Output Apparent Power （VA）</td>
<td width="125">3960</td>
<td width="125">5500</td>
<td width="125">6600</td>
<td width="125">7700</td>
<td width="125">8360</td>
<td width="125">8800</td>
<td width="125">11000</td>
</tr>
<tr>
<td width="176">Rated AC Input/Output Current（A）</td>
<td width="125">16.4/15.7</td>
<td width="125">22.7/21.7</td>
<td width="125">27.3/26.1</td>
<td width="125">31.9/30.5</td>
<td width="125">34.5/33</td>
<td width="125">36.4/34.8</td>
<td width="125">45.5/43.5</td>
</tr>
<tr>
<td width="176">Max AC Input/Output Current（A）</td>
<td width="125">18/17.2</td>
<td width="125">25/23.9</td>
<td width="125">30/28.7</td>
<td width="125">35.0/33.5</td>
<td width="125">38/36.3</td>
<td width="125">40/38.3</td>
<td width="125">50/47.9</td>
</tr>
<tr>
<td width="176">Max Continuous AC Passthrough (grid to load)（A）</td>
<td colspan="2" width="250">35</td>
<td width="125">40</td>
<td colspan="4" width="500">50</td>
</tr>
<tr>
<td width="176">Peak Power (off-grid)（W）</td>
<td colspan="7" width="875">2 times of rated power,10s</td>
</tr>
<tr>
<td width="176">Rated Input/Output Voltage/Range(V)</td>
<td colspan="7" width="875">220V/230 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="176">Grid Connection Form</td>
<td colspan="7" width="875">L+N+PE</td>
</tr>
<tr>
<td width="176">Rated Input/Output Grid Frequency/Range</td>
<td colspan="7" width="875">50Hz/45Hz-55Hz     60Hz/55Hz-65Hz</td>
</tr>
<tr>
<td width="176">Power Factor Adjustment Range</td>
<td colspan="7" width="875">0.8 leading-0.8lagging</td>
</tr>
<tr>
<td width="176">Total Current Harmonic Distortion THDi</td>
<td colspan="7" width="875">&#60;3% (of nominal power)</td>
</tr>
<tr>
<td width="176">DC Injection Current</td>
<td colspan="7" width="875">&#60;0.5%ln</td>
</tr>
<tr>
<td width="176"><strong>Efficiency</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Max Efficiency</td>
<td colspan="7" width="875">97.60%</td>
</tr>
<tr>
<td width="176">Euro Efficiency</td>
<td colspan="7" width="875">96.50%</td>
</tr>
<tr>
<td width="176">MPPT Efficiency</td>
<td colspan="7" width="875">＞99%</td>
</tr>
<tr>
<td width="176"><strong>Equipment Protection</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Integrated</td>
<td colspan="7" width="875">DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection</td>
</tr>
<tr>
<td width="176">Surge Protection Level</td>
<td colspan="7" width="875">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="176"><strong>Interface</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Communication Interface</td>
<td colspan="7" width="875">WIFI/RS485/CAN</td>
</tr>
<tr>
<td width="176">LCD/LED Display</td>
<td colspan="7" width="875">LCD</td>
</tr>
<tr>
<td width="176"><strong>General Data</strong></td>
<td colspan="7" width="875"></td>
</tr>
<tr>
<td width="176">Operating Temperature Range</td>
<td colspan="7" width="875">-40 to +60℃, &#62;45℃ Derating</td>
</tr>
<tr>
<td width="176">Permissible Ambient Humidity</td>
<td colspan="7" width="875">0~100%</td>
</tr>
<tr>
<td width="176">Permissible Altitude</td>
<td colspan="7" width="875">2500m</td>
</tr>
<tr>
<td width="176">Noise</td>
<td colspan="7" width="875">＜45</td>
</tr>
<tr>
<td width="176">Ingress Protection(IP) Rating</td>
<td colspan="7" width="875">IP 65</td>
</tr>
<tr>
<td width="176">Inverter Topology</td>
<td colspan="7" width="875">Non-Isolated</td>
</tr>
<tr>
<td width="176">Over Voltage Category</td>
<td colspan="7" width="875">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="176">Cabinet size（W*H*D）[mm]</td>
<td colspan="7" width="875">330×580×232 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="176">Weight[kg]</td>
<td colspan="7" width="875">24.9</td>
</tr>
<tr>
<td width="176">Warranty</td>
<td colspan="7" width="875">5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy</td>
</tr>
<tr>
<td width="176">Type Of Cooling</td>
<td colspan="7" width="875">Intelligent air cooling</td>
</tr>
<tr>
<td width="176">Grid Regulation</td>
<td colspan="7" width="875">IEC 61727,IEC 62116,CEI 0-21,EN 50549，NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="176">Safety EMC/Standard</td>
<td colspan="7" width="875">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<ul>
<li>Colorful touch LCD, IP65 protection degree</li>
<li>AC couple to retrofit existing solar system</li>
<li>Max. 16 pcs parallel for on-grid and off-grid</li>
<li>operation; Support multiple batteries parallel</li>
<li>Max. charging/discharging current of 190A</li>
<li>6 time periods for battery charging/discharging</li>
<li>Support storing energy from diesel generator</li>
</ul>